Installs in Federal Heights
Strata Heat Pumps installs heat pumps in Federal Heights, in every ZIP code listed on this page. The online estimate gives a price range and your rebates for a Federal Heights address in about two minutes.
Federal Heights homes need different heat pump plans
Federal Heights has 5,403 homes in 1.775 square miles, and 5,162 are occupied. Census figures show a compact housing mix that differs sharply from Adams County. The town has 46.8% mobile homes and 32.2% homes in multi-unit buildings. Adams County has 5.8% mobile homes and 22.9% homes in multi-unit buildings.
Only 17.6% of Federal Heights homes are detached houses, compared with 62.6% across Adams County. The town also has fewer rooms, with a median of 4.4 versus 5.8 in the county. That mix calls for system choices based on the individual home, its existing ducts, and the rooms that need heating and cooling.
Federal Heights homes have a median build year of 1990, matching Adams County. Homes built from 1980 to 1999 make up 35.3% of the town, while 28.1% were built from 1960 to 1979. Those age groups guide the starting load in our estimate tool, but we measure the home before installation.
Federal Heights differs from nearby towns
Federal Heights has a far larger mobile-home share than its nearby towns. Shaw Heights has 1,697 homes, 88% detached homes, and 1.9% in multi-unit buildings. Sherrelwood has 6,568 homes, with 72.5% detached and 24.2% in multi-unit buildings. Federal Heights instead has 17.6% detached homes and 32.2% in multi-unit buildings.
Westminster has 50,166 homes and a median build year of 1987. Its 33% multi-unit share is close to Federal Heights at 32.2%, but Westminster has 55.8% detached homes. Twin Lakes has 3,282 homes, 78.1% detached homes, and 15.5% in multi-unit buildings. Detached homes more often have central duct systems to assess for a ducted replacement.
The nearby housing ages also point to different starting conditions. Shaw Heights has a median build year of 1968, Sherrelwood 1966, Westminster 1987, and Twin Lakes 1976. Federal Heights has 2.5% of homes built before 1960, below Shaw Heights at 17.4%, Sherrelwood at 30.9%, and Twin Lakes at 35.3%. Older homes are more likely to need a ductless or dual-fuel discussion when ducts are limited.
How Federal Heights homes heat today
Utility gas heats 67.2% of Federal Heights homes. That is close to Adams County at 68.8% and Colorado at 66.7%. For a home with a gas furnace, a ducted heat pump can replace central heating and add cooling if the ducts fit. A dual-fuel system keeps the gas furnace for the coldest hours.
Electricity heats 30.2% of homes here, above Adams County at 27.1% and Colorado at 25.2%. Ductless heat pumps fit homes without ducts, additions, condos, and room-focused heating needs. They also cool. In a town where 27.4% of homes are in buildings with 10 or more units, each residence needs its own equipment and access review.
Gas use here sits below nearby Westminster at 69.4% and Twin Lakes at 72.7%, but above Sherrelwood at 68.4% only by a small amount. Shaw Heights has 82.2% gas heat. Electric heat is 34.9% in ZIP code 80260, compared with 30.2% for Federal Heights. Existing fuel shapes the rebate path, while the home layout determines the system design.
Ducted, dual-fuel, and ductless systems
Ducted heat pumps suit homes with usable central ducts. They move heat instead of burning fuel, and they provide cooling. Federal Heights has 17.6% detached homes and 3.4% attached homes, where an existing duct system can support a whole-home ducted design. We check ducts and the electrical panel before we install.
Dual fuel fits gas-heated homes that want a heat pump while retaining the gas furnace for the coldest hours. Since 67.2% of homes here use utility gas, that option belongs in many replacement conversations. It also fits homes where the current furnace and ducts remain suitable after our inspection.
Ductless systems suit the town's 46.8% mobile-home share and 32.2% multi-unit share when a home lacks ducts or needs room-by-room equipment. Our estimate tool uses 500 sq ft for each ductless indoor unit and prices up to 5 indoor units before a custom quote. The right number of indoor units follows the floor plan, not a one-size rule.
Sizing heat pumps for Federal Heights cold and altitude
We size each system to 1°F outdoors and 70°F indoors. Our sizing uses 5,300 ft, where an air-source unit loses 18% of heat output. At the design temperature, the estimate uses a coefficient of performance of 2. Those conditions matter because altitude and deep cold reduce an air-source heat pump's output.
For the example 2,000 square foot, 2-story, gas-heated home built from 1980 to 1999, the design heat load is 2.8 tons. The starting electrical requirement is 30 A. A home of the same size and layout built before 1960 has a design load of 3.4 tons, while a home built from 2010 or later has 2.0 tons. Build year changes the starting load.
Federal Heights has 35.3% of homes built from 1980 to 1999, so the example aligns with the town's largest build group. Homes from 1960 to 1979 account for 28.1% and start at 3.2 tons for the same example profile. Homes built from 2000 to 2009 account for 17.7% and start at 2.4 tons. We verify the result by measuring the home, reviewing ducts, and checking the electrical panel.
Example prices and rebates in Federal Heights
For the example home, a ducted heat pump is $15,100 to $27,900 before rebates and $8,400 to $21,200 after rebates. A dual-fuel system is $12,100 to $22,500 before rebates and $5,400 to $15,800 after rebates. Our estimate tool provides these ranges from the home details, system type, sizing conditions, and current rebate settings.
A 1,500 square foot home with electric heat and no ducts starts with 3 ductless indoor units in the example. Its ductless range is $11,800 to $19,200 before rebates and $7,800 to $15,200 after rebates. Ductless pricing depends on the indoor-unit count. One indoor unit is $5,800 to $9,400, while five are $17,800 to $28,900.
For a gas-heated home using a 3-ton ducted heat pump, total listed rebates are $7,000. They stack as the Xcel Energy rebate ($4,500), the State of Colorado Heat Pump Discount ($1,000) and the Power Ahead Colorado rebate ($1,500). For a home now heated with electricity, the total is $4,700, made up of the Xcel Energy rebate ($2,200), the State of Colorado Heat Pump Discount ($1,000) and the Power Ahead Colorado rebate ($1,500). The State of Colorado Heat Pump Discount comes off the invoice, and we file every rebate for the homeowner.
ZIP code 80260 and the next steps
Federal Heights uses ZIP code 80260, whose main town is Thornton. Census figures for 80260 show 12,841 homes and a median build year of 1984. That ZIP is older than Federal Heights at 1990. It has 22.7% detached homes, above Federal Heights at 17.6%, and 34.3% in multi-unit buildings, above the town's 32.2%.
Gas heat reaches 63.4% in 80260, below Federal Heights at 67.2%. Electric heat reaches 34.9%, above the town at 30.2%. Homes built before 1960 are 2.6% in the ZIP and 2.5% in Federal Heights. Homes built from 2010 or later are 10.6% in the ZIP, below the town's 16.4%. These differences make the address and current heating equipment important inputs.
The online estimate takes about two minutes, and a winter gas bill makes it more accurate. We install Mitsubishi, Bosch, Daikin, Carrier, and Trane equipment. Most installations take one day. Jobs with several ductless units can take two or three days. The federal 25C credit ended for systems installed after 2025-12-31.
Federal Heights in numbers
| Homes | Median year built | Built before 1960 | Built 2010 or later | Gas heat | Electric heat | Propane | |
|---|---|---|---|---|---|---|---|
| Federal Heights | 5,403 | 1990 | 2.5% | 16.4% | 67.2% | 30.2% | 1.4% |
| Adams County | 191,765 | 1990 | 13.5% | 14.9% | 68.8% | 27.1% | 2% |
| Colorado | 2,545,124 | 1987 | 16.3% | 14% | 66.7% | 25.2% | 4.9% |
| ZIP | Main town | Homes | Median year built | Heat with gas | Electric utility | Install area |
|---|---|---|---|---|---|---|
| 80260 | Thornton | 12,841 | 1984 | 63.4% | Xcel Energy | Yes |
Systems and rebates in Adams County
- Ducted heat pump in Adams CountyPrices by home age and the Adams rebates for this system.
- Dual-fuel heat pump in Adams CountyPrices by home age and the Adams rebates for this system.
- Ductless mini-split in Adams CountyPrices by home age and the Adams rebates for this system.
- Heat pump rebates in Adams County$7,000 on a 3-ton gas home, program by program.
- Pool heat pumps in Adams CountyPool and spa heat pumps: local code rules, running cost and the swim season.
Other towns we install in
Questions we hear
What heat pump system fits a Federal Heights home with central ducts?
A ducted heat pump fits a home with usable central ducts and adds cooling. Federal Heights has 17.6% detached homes and 3.4% attached homes, where central equipment is a starting point to review. For gas-heated homes, dual fuel keeps the gas furnace for the coldest hours. We measure the home, inspect ducts, and check the electrical panel before installation.
What is the example heat pump size for Federal Heights?
For the 2,000 square foot, 2-story example home with a gas furnace built from 1980 to 1999, the design heat load is 2.8 tons. We size to 1°F outdoors and 70°F indoors, using 5,300 ft. The estimate accounts for 18% lost heat output at that elevation and starts with 30 A electrical service.
What rebates apply to a gas-heated home in Federal Heights?
For a gas-heated home using a 3-ton ducted heat pump, the total listed rebates are $7,000. The listed stack is the Xcel Energy rebate ($4,500), the State of Colorado Heat Pump Discount ($1,000) and the Power Ahead Colorado rebate ($1,500). The Xcel Energy rebate applies to customers with a gas furnace, gas boiler, or propane heat. The State of Colorado Heat Pump Discount applies to every Colorado home and comes off the invoice.
How much does the example dual-fuel system cost?
For the 2,000 square foot, 2-story example home built from 1980 to 1999, a dual-fuel system is $12,100 to $22,500 before rebates. The range is $5,400 to $15,800 after rebates. Dual fuel pairs a heat pump with the existing gas furnace for the coldest hours. The final equipment choice follows the measured load, ducts, and electrical-panel review.
How does ZIP code 80260 differ from Federal Heights housing?
ZIP code 80260 has 12,841 homes and a median build year of 1984, compared with 1990 in Federal Heights. Electric heat is 34.9% in the ZIP and 30.2% in the town. Multi-unit homes are 34.3% in 80260 and 32.2% in Federal Heights. Those differences affect the starting conversation about ducts, fuel, and equipment layout.